Описание серии
Аналогично рисунку
Тип
Customizable sewage lifting unit with solids separation system for installation in a building or in a pump chamber for outdoor installation.
Обозначение
Example: | Wilo-EMUport FTS MG 1500 |
---|---|
FTS | Solids separation system (custom version) |
F | Version (M = compact version, F = large version) |
G | Type of installation (G = in building, S = with PE-HD pump chamber) |
1500 | FG = outer diameter of the collection reservoir in mm FS = shaft diameter in mm MG = installation depth below inlet floor in mm MS = shaft inside diameter in mm |
Применение
Pumping of untreated sewage that cannot be returned to the sewer system using natural falls, and for the draining of objects that are below the backflow level (according to DIN EN 12056/ DIN 1986-100).
Особенности/преимущества продукции
Технические характеристики
Оснащение/функции
Описание/конструкция
Fully submersible sewage lifting unit ready for connection with solids separation. All-in-one gastight and watertight collection reservoir without constructive welded joints, as well as two separately-lockable solids separation reservoirs. The collection reservoir has rounded edges and the bottom of the basin is bevelled. This prevents deposits and the drying of solids. With pre-filtering in the solids separation reservoirs, the solids are filtered from the fluid and only pre-filtered sewage is directed to the collection reservoir. Pumping is performed by two high-performance submersible sewage pumps in versions IP55 or IP68 in dry well installation. The pumps are designed as a redundant double-pump system and run in alternating operation. Level management can be performed via three float switches or a level probe.
On request, the system can be equipped with automatic backflushing to the collection reservoir and installed directly into a pump chamber made of PE-HD. For management, the corresponding switchgear of the SC-L and CC-L series can be selected as an accessory.
Материалы
Комплект поставки
Опции
Определение параметров
The installation must be configured for the maximum amount of sewage occurring, including a possible additional peak flow. The pumps must be configured for a minimum flow velocity of 0.7 m/s in the discharge pipeline (e.g. min. 18.55 m³/h for a DN 100 pipe).
The manometric delivery head is calculated as the maximum geodesic head + pipeline friction losses + pumping station losses.
Рабочее поле
Оснащение/функции
Конструкция | |
---|---|
Насос входит в комплект поставки | • |
Однонасосная установка | - |
Двухнасосная установка | • |
в шахте PE-HD | • |
Применение | |
Напольный монтаж | • |
Монтаж под полом | • |
Оснащение/функции | |
прибор управления | Вє |
устройства плавного пуска | Опция |
Частотный преобразователь | Вє |
Автоматический предохранительный выключатель, действующий при появлении тока утечки | Вє |
Контроль уровня: при помощи пневматического датчика давления | - |
Контроль уровня: при помощи датчика уровня | • |
Передача данных: по кабелю | Вє |
Передача данных: посредством модуля GSM/UMTS | Вє |
Подключение к резервному источнику тока | Вє |
Выбор точки подсоединения приточных трубопроводов на месте. | • |
Готовность к подключению | - |
Распределительный шкаф для наружного монтажа | Вє |
Монтажные чертежи