(N)TSCGEWÖU
Based on DIN VDE 0250 Part 813
- PHASE CONDUCTORS
MATERIAL: tinned copper
CONSTRUCTION: class 5 VDE 0295 (IEC 60228) (special construction to get improved flexibility)
INSULATION MATERIAL: 3GI3 quality rubber compound, according to VDE 0207 Part 20
SEMICONDUCTIVE LAYERS: semiconductive tape over the conductor and inner and outer semiconductive rubber layer on the insulation
- EARTH CONDUCTORS
MATERIAL: tinned copper
CONSTRUCTION: class 5 VDE 0295 (IEC 60228) (special construction to get improved flexibility)
COVERING MATERIAL: semiconductive layer
CENTRAL FILLER
MATERIAL: semiconductive compound on textile polyester support
CORES ASSEMBLY
ASSEMBLY: twisted cores with earth conductor split into 3 parts
SEPARATOR ON THE TWISTED ASSEMBLY: semiconductive tape around the twisted cores
- INNER SHEATH
MATERIAL: special EPR compound waterproof proofing GM1b quality,according to VDE 0207 Part 21
THICKNESS: according to VDE 0250 Part 813 (table 2)
- OUTER SHEATH
MATERIAL: special CM rubber compound waterproof proofing 5GM3 quality, according to VDE 0207 Part 21
THICKNESS: according to VDE 0250 Part 813 (table 2)
COLOUR: black
APPLICATION
Heavy duty flexible medium voltage power cable designed for permanent immersion in fresh or salt water where mechanical stress is likely. Suitable for immersion at depths to 300 meters.
For pumps, dredgers, floating docks and for trailing operations with opencast mining equipment. The cable is unarmoured and therefore is not suitable for under-water power transmission or installation in a waterway or where mechanical damage is possible.