(N)3GHSSYCY
Based on VDE 0250 Part 605
- PHASE CONDUCTORS
MATERIAL: bare copper
CONSTRUCTION: class 5 VDE 0295 (IEC 60228)
INSULATION MATERIAL: 3GI3 quality rubber compound, according to VDE 0207 Part 20
SEMICONDUCTIVE LAYERS: semiconductive tape over the conductor and inner and outer semiconductive rubber layer on the insulation
- PROTECTIVE EARTH CONDUCTORS
MATERIAL: bare copper
CONSTRUCTION: individual copper wire screen
- CONTROL CONDUCTORS
MATERIAL: tinned copper
CONSTRUCTION: class 5 VDE 0295 (IEC 60228)
INSULATION MATERIAL: 3GI3 quality rubber compound, according to VDE 0207 Part 20
- FIRST INNER SHEATH
MATERIAL: PVC, DMV6 (YM5) quality
- MINITORING CONDUCTOR
MATERIAL: bare copper
CONSTRUCTION: copper wire screen over the first inner sheath
- SECOND INNER SHEATH
MATERIAL: PVC, DMV6 (YM5) quality
- ARMOR
MATERIAL: steel wire
CONSTRUCTION: steel wire braid over the second inner sheath
- OUTER SHEATH
MATERIAL: PVC, DMV6 (YM5) quality
COLOUR: red
APPLICATION
Flexible cable for energy supply of MV equipment, in tunnelling and underground mining applications, according to VDE 0250 Part 605 Standard, as far as applicable.